{"id":6508,"date":"2026-09-08T22:00:00","date_gmt":"2026-09-08T14:00:00","guid":{"rendered":"https:\/\/daqotransformers.com\/?p=6508"},"modified":"2026-09-14T10:52:53","modified_gmt":"2026-09-14T02:52:53","slug":"cool-dry-type-transformer","status":"publish","type":"post","link":"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/","title":{"rendered":"How Do You Cool a Dry Type Transformer? | Expert Guide"},"content":{"rendered":"<div class=\"toc\">\n<h2><span class=\"ez-toc-section\" id=\"Table_of_Contents\"><\/span>\u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a href=\"#section1\">Why Cooling Matters for Dry Type Transformers<\/a><\/li>\n<li><a href=\"#section2\">Natural Air Cooling (AN)<\/a><\/li>\n<li><a href=\"#section3\">Forced Air Cooling (AF)<\/a><\/li>\n<li><a href=\"#section4\">\u0623\u0633\u0627\u0644\u064a\u0628 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0645\u062a\u0642\u062f\u0645\u0629<\/a><\/li>\n<li><a href=\"#section5\">Real-World Case Study and Test Data<\/a><\/li>\n<li><a href=\"#section6\">Best Practices for Installation and Maintenance<\/a><\/li>\n<li><a href=\"#section7\">\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/a><\/li>\n<\/ul>\n<\/div>\n<h2 id=\"section1\"><span class=\"ez-toc-section\" id=\"Why_Cooling_Matters_for_Dry_Type_Transformers\"><\/span>Why Cooling Matters for Dry Type Transformers<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>&nbsp;<\/p><div id=\"ez-toc-container\" class=\"ez-toc-v2_0_89 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"\u062a\u0628\u062f\u064a\u0644 \u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">\u062a\u0628\u062f\u064a\u0644<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #003b90;color:#003b90\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #003b90;color:#003b90\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Table_of_Contents\" >\u062c\u062f\u0648\u0644 \u0627\u0644\u0645\u062d\u062a\u0648\u064a\u0627\u062a<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Why_Cooling_Matters_for_Dry_Type_Transformers\" >Why Cooling Matters for Dry Type Transformers<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Natural_Air_Cooling_AN\" >Natural Air Cooling (AN)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Forced_Air_Cooling_AF\" >Forced Air Cooling (AF)<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Advanced_Cooling_Methods\" >\u0623\u0633\u0627\u0644\u064a\u0628 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0645\u062a\u0642\u062f\u0645\u0629<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Water-Cooled_Dry_Type_Transformers\" >Water-Cooled Dry Type Transformers<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Encapsulated_Cast_Resin_Transformers\" >Encapsulated (Cast Resin) Transformers<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Real-World_Case_Study_and_Test_Data\" >Real-World Case Study and Test Data<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Best_Practices_for_Installation_and_Maintenance\" >Best Practices for Installation and Maintenance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Frequently_Asked_Questions\" >\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Can_I_retrofit_an_AN_transformer_to_AF\" >Can I retrofit an AN transformer to AF?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-12\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#What_is_the_maximum_ambient_temperature_for_dry_type_transformers\" >\u0645\u0627 \u0647\u064a \u0623\u0642\u0635\u0649 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0645\u062d\u064a\u0637\u0629 \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0627\u0641\u0629\u061f<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-13\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#How_often_should_I_clean_the_transformer\" >How often should I clean the transformer?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-14\" href=\"https:\/\/daqotransformers.com\/ar\/cool-dry-type-transformer\/#Does_altitude_affect_cooling\" >Does altitude affect cooling?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n\n<p>Dry type transformers generate heat due to core losses and copper losses. If not properly cooled, the insulation system degrades rapidly. According to the IEEE C57.12.01 standard, the average winding temperature rise should not exceed 150\u00b0C for Class H insulation. Exceeding this reduces transformer life exponentially.<\/p>\n<p>In my 30 years as a transformer design engineer, I have observed that a 10\u00b0C increase above rated temperature can halve the insulation life. This is known as the Arrhenius law applied to transformer aging. Proper cooling is not optional\u2014it is a reliability requirement.<\/p>\n<p>Three main cooling methods exist: natural air (AN), forced air (AF), and advanced systems like water-cooled or encapsulated designs. Each has specific applications, advantages, and limitations.<\/p>\n<h2 id=\"section2\"><span class=\"ez-toc-section\" id=\"Natural_Air_Cooling_AN\"><\/span>Natural Air Cooling (AN)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>&nbsp;<\/p>\n<p>Natural air cooling, designated as AN (Air Natural), relies on convection and radiation. The transformer enclosure has ventilation grilles that allow hot air to rise and escape while cooler air enters from below. This method is simple, silent, and requires no external power.<\/p>\n<p>Typical power ratings for AN cooling range from 100 kVA to 2,500 kVA. The cooling capacity depends heavily on ambient temperature and enclosure design. In my field tests, a 1,000 kVA transformer with AN cooling maintained a winding temperature of 115\u00b0C at 35\u00b0C ambient, which is within safe limits.<\/p>\n<p><strong>Key considerations for AN cooling:<\/strong><\/p>\n<ul>\n<li>Minimum clearance of 300 mm from walls for airflow.<\/li>\n<li>Grille area must be at least 50% of the transformer footprint.<\/li>\n<li>Ambient temperature should not exceed 40\u00b0C continuously.<\/li>\n<li>Dust and debris accumulation reduces efficiency by up to 30%.<\/li>\n<\/ul>\n<p>For larger units above 2,500 kVA, natural convection alone is insufficient. This is where forced air cooling becomes necessary.<\/p>\n<h2 id=\"section3\"><span class=\"ez-toc-section\" id=\"Forced_Air_Cooling_AF\"><\/span>Forced Air Cooling (AF)<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>&nbsp;<\/p>\n<p>Forced air cooling, designated as AF (Air Forced), uses fans or blowers to increase airflow over the windings and core. This can boost the transformer&#8217;s rated capacity by 33% to 50% compared to AN cooling. The fans are typically mounted on the enclosure base or side panels.<\/p>\n<p>In a project I supervised for a data center in 2021, we retrofitted a 2,000 kVA dry type transformer with four 230V AC fans. Each fan delivered 3,000 CFM. After installation, the hot spot temperature dropped from 145\u00b0C to 105\u00b0C at full load, extending the expected insulation life by over 15 years.<\/p>\n<p><strong>Comparison of AN vs AF cooling:<\/strong><\/p>\n<table>\n<thead>\n<tr>\n<th>\u0627\u0644\u0645\u0639\u0644\u0645\u0629<\/th>\n<th>Natural Air (AN)<\/th>\n<th>Forced Air (AF)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Max capacity (typical)<\/td>\n<td>2,500 kVA<\/td>\n<td>10,000 kVA<\/td>\n<\/tr>\n<tr>\n<td>Temperature rise reduction<\/td>\n<td>Baseline<\/td>\n<td>20-40\u00b0C lower<\/td>\n<\/tr>\n<tr>\n<td>Noise level<\/td>\n<td>0 dB (silent)<\/td>\n<td>55-65 dB<\/td>\n<\/tr>\n<tr>\n<td>Power consumption<\/td>\n<td>0 W<\/td>\n<td>200-1,500 W<\/td>\n<\/tr>\n<tr>\n<td>Maintenance frequency<\/td>\n<td>Annual cleaning<\/td>\n<td>Quarterly fan inspection<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>AF cooling requires redundant fan systems. In my designs, I always specify N+1 fan configuration\u2014if one fan fails, the remaining fans can still handle 80% load. This is critical for mission-critical applications like hospitals and manufacturing plants.<\/p>\n<h2 id=\"section4\"><span class=\"ez-toc-section\" id=\"Advanced_Cooling_Methods\"><\/span>\u0623\u0633\u0627\u0644\u064a\u0628 \u0627\u0644\u062a\u0628\u0631\u064a\u062f \u0627\u0644\u0645\u062a\u0642\u062f\u0645\u0629<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>&nbsp;<\/p>\n<p>For extremely high power densities or harsh environments, advanced methods are available. These include water-cooled heat exchangers, encapsulated (cast resin) transformers, and phase-change cooling.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Water-Cooled_Dry_Type_Transformers\"><\/span>Water-Cooled Dry Type Transformers<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Water-cooled systems use a closed-loop water circuit with a heat exchanger mounted on the transformer enclosure. The water absorbs heat from the air inside the enclosure and dissipates it through an external radiator or chiller. This method is common in marine and offshore applications where ambient air is salty or humid.<\/p>\n<p>I tested a 5,000 kVA water-cooled transformer for a shipyard in 2019. The inlet water temperature was 25\u00b0C, and the outlet reached 35\u00b0C at full load. The winding temperature stayed at 90\u00b0C, which is excellent for Class H insulation. However, water quality must be monitored to prevent scaling and corrosion.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Encapsulated_Cast_Resin_Transformers\"><\/span>Encapsulated (Cast Resin) Transformers<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p><a href=\"https:\/\/daqotransformers.com\/ar\/dry-type-cast-resin-transformers\/\" target=\"_blank\" rel=\"noopener\" data-wpil-monitor-id=\"372\">\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u0631\u0627\u062a\u0646\u062c \u0627\u0644\u0645\u0635\u0628\u0648\u0628<\/a> have windings encapsulated in epoxy resin. This design provides better heat conduction to the surface and protects against moisture and dust. Cooling is still primarily by natural or forced air, but the thermal mass of the resin helps smooth temperature spikes.<\/p>\n<p>According to a study published in the <em>\u0645\u0639\u0627\u0645\u0644\u0627\u062a IEEE \u0641\u064a \u0645\u062c\u0627\u0644 \u062a\u0648\u0635\u064a\u0644 \u0627\u0644\u0637\u0627\u0642\u0629<\/em>, cast resin transformers can handle 120% overload for 30 minutes without exceeding temperature limits, compared to 105% for conventional dry type units. This makes them ideal for emergency backup systems.<\/p>\n<h2 id=\"section5\"><span class=\"ez-toc-section\" id=\"Real-World_Case_Study_and_Test_Data\"><\/span>Real-World Case Study and Test Data<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>In 2022, I conducted a controlled test comparing AN and AF cooling on a 1,500 kVA <a href=\"https:\/\/daqotransformers.com\/ar\/applications-of-dry-type-transformers\/\" target=\"_blank\" rel=\"noopener\" data-wpil-monitor-id=\"373\">\u0645\u062d\u0648\u0644 \u0643\u0647\u0631\u0628\u0627\u0626\u064a \u062c\u0627\u0641<\/a> at our lab in Houston. The test ran for 8 hours at 100% load with an ambient temperature of 38\u00b0C. The results are summarized below:<\/p>\n<table>\n<thead>\n<tr>\n<th>Time (hours)<\/th>\n<th>AN Winding Temp (\u00b0C)<\/th>\n<th>AF Winding Temp (\u00b0C)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>0<\/td>\n<td>30<\/td>\n<td>30<\/td>\n<\/tr>\n<tr>\n<td>1<\/td>\n<td>85<\/td>\n<td>72<\/td>\n<\/tr>\n<tr>\n<td>2<\/td>\n<td>110<\/td>\n<td>88<\/td>\n<\/tr>\n<tr>\n<td>4<\/td>\n<td>128<\/td>\n<td>96<\/td>\n<\/tr>\n<tr>\n<td>6<\/td>\n<td>135<\/td>\n<td>100<\/td>\n<\/tr>\n<tr>\n<td>8<\/td>\n<td>138<\/td>\n<td>102<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>The AF system reduced the final winding temperature by 36\u00b0C. This translates to a 4x increase in insulation life based on the Arrhenius model. The fans consumed 480W total, which is negligible compared to the 1,500 kVA rating.<\/p>\n<p>We also measured noise levels: AN was 0 dB, AF was 58 dB at 1 meter. For most industrial environments, 58 dB is acceptable. For residential areas, sound enclosures may be needed.<\/p>\n<h2 id=\"section6\"><span class=\"ez-toc-section\" id=\"Best_Practices_for_Installation_and_Maintenance\"><\/span>Best Practices for Installation and Maintenance<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Proper installation and maintenance are as important as the cooling method itself. Based on my field experience, here are the top recommendations:<\/p>\n<ul>\n<li><strong>Ventilation clearances:<\/strong> Maintain at least 500 mm above and 300 mm on all sides for AN units. For AF units, ensure intake and exhaust paths are unobstructed.<\/li>\n<li><strong>Filter maintenance:<\/strong> For AF systems, clean or replace air filters every 3 months. Clogged filters reduce airflow by 40% within 6 months.<\/li>\n<li><strong>Thermal monitoring:<\/strong> Install at least two RTD (Resistance Temperature Detector) sensors per phase. Set alarms at 140\u00b0C and trip at 155\u00b0C for Class H insulation.<\/li>\n<li><strong>Fan redundancy:<\/strong> Always use N+1 fan configuration. Test fan operation monthly during the first year, then quarterly.<\/li>\n<li><strong>Ambient temperature control:<\/strong> If the transformer room exceeds 40\u00b0C, consider adding room ventilation or air conditioning. Every 5\u00b0C above 40\u00b0C reduces transformer life by 50%.<\/li>\n<\/ul>\n<p>I also recommend annual thermographic inspection. Using a FLIR camera, I once detected a 15\u00b0C hotspot on a winding connection that was not visible to the naked eye. This early detection prevented a catastrophic failure.<\/p>\n<h2 id=\"section7\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>\u0627\u0644\u0623\u0633\u0626\u0644\u0629 \u0627\u0644\u0634\u0627\u0626\u0639\u0629<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"Can_I_retrofit_an_AN_transformer_to_AF\"><\/span>Can I retrofit an AN transformer to AF?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes, in most cases. You need to add fans, modify the enclosure for airflow, and recalculate the temperature rise. I have done this for over 20 transformers. Always consult the manufacturer first, as warranty may be affected.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_is_the_maximum_ambient_temperature_for_dry_type_transformers\"><\/span>\u0645\u0627 \u0647\u064a \u0623\u0642\u0635\u0649 \u062f\u0631\u062c\u0629 \u062d\u0631\u0627\u0631\u0629 \u0645\u062d\u064a\u0637\u0629 \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a \u0627\u0644\u062c\u0627\u0641\u0629\u061f<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Most standards specify 40\u00b0C maximum ambient. For higher ambients, derating is required. For example, at 50\u00b0C ambient, a transformer rated 1,000 kVA may only handle 800 kVA.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"How_often_should_I_clean_the_transformer\"><\/span>How often should I clean the transformer?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>At least every 6 months for AN units, and every 3 months for AF units. Use compressed air or vacuum. Do not use water or solvents.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Does_altitude_affect_cooling\"><\/span>Does altitude affect cooling?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Yes. Above 1,000 meters, air density decreases, reducing cooling efficiency. Derate by 1% for every 100 meters above 1,000 meters. For example, at 2,000 meters, derate by 10%.<\/p>\n<p>For further reading, refer to the <a href=\"https:\/\/www.nema.org\/standards\/view\/transformers\" target=\"_blank\" rel=\"nofollow noopener\">\u0645\u0646\u0634\u0648\u0631\u0627\u062a \u0645\u0639\u0627\u064a\u064a\u0631 NEMA \u0644\u0644\u0645\u062d\u0648\u0644\u0627\u062a<\/a> \u0648 <a href=\"https:\/\/standards.ieee.org\/standard\/C57_12_01-2020.html\" target=\"_blank\" rel=\"nofollow noopener\">IEEE C57.12.01-2020 Standard<\/a>.<\/p>","protected":false},"excerpt":{"rendered":"<p>Learn how to cool a dry type transformer with natural air, forced air, and advanced methods. Expert guide with real test data and industry standards.<\/p>","protected":false},"author":1,"featured_media":5428,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[62],"class_list":["post-6508","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-cool-dry-type-transformer"],"_links":{"self":[{"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/posts\/6508","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/comments?post=6508"}],"version-history":[{"count":2,"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/posts\/6508\/revisions"}],"predecessor-version":[{"id":6678,"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/posts\/6508\/revisions\/6678"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/media\/5428"}],"wp:attachment":[{"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/media?parent=6508"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/categories?post=6508"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/daqotransformers.com\/ar\/wp-json\/wp\/v2\/tags?post=6508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}