{"id":6488,"date":"2026-07-31T17:00:00","date_gmt":"2026-07-31T09:00:00","guid":{"rendered":"https:\/\/daqotransformers.com\/?p=6488"},"modified":"2026-07-10T16:59:46","modified_gmt":"2026-07-10T08:59:46","slug":"what-is-current-transformer-dry-type","status":"publish","type":"post","link":"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/","title":{"rendered":"\u00bfQu\u00e9 es un transformador de corriente de tipo seco? \u2013 Gu\u00eda completa"},"content":{"rendered":"<div class=\"table-of-contents\">\n<p><strong>\u00cdndice<\/strong><\/p><div id=\"ez-toc-container\" class=\"ez-toc-v2_0_80 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">\u00cdndice<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Mostrar\/ocultar \u00edndice\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #003b90;color:#003b90\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #003b90;color:#003b90\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#What_is_a_Dry_Type_Current_Transformer\" >\u00bfQu\u00e9 es un transformador de corriente de tipo seco?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#How_Dry_Type_CTs_Work_Core_Principles\" >C\u00f3mo funcionan los tratamientos de toxina col\u00f3nica de tipo seco: Principios b\u00e1sicos<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#Types_of_Insulation_Materials_Used\" >Tipos de materiales aislantes utilizados<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#Key_Advantages_Over_Oil-Filled_CTs\" >Ventajas clave sobre los CT llenos de aceite<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#Real-World_Applications_and_Performance_Data\" >Aplicaciones en el mundo real y datos de rendimiento<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#Installation_and_Maintenance_Guidelines\" >Directrices de instalaci\u00f3n y mantenimiento<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#Frequently_Asked_Questions\" >Preguntas frecuentes<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#What_is_the_difference_between_dry_type_and_oil-filled_current_transformers\" >\u00bfCu\u00e1l es la diferencia entre los transformadores de corriente de tipo seco y los transformadores de corriente llenos de aceite?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#Can_dry_type_CTs_be_used_outdoors\" >\u00bfSe pueden utilizar las toallitas de tipo seco en exteriores?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#How_do_I_select_the_correct_dry_type_CT_for_my_application\" >\u00bfC\u00f3mo selecciono el tipo de CT seco correcto para mi aplicaci\u00f3n?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/daqotransformers.com\/es\/what-is-current-transformer-dry-type\/#What_causes_a_dry_type_CT_to_fail\" >\u00bfQu\u00e9 causa la falla de una tomograf\u00eda computarizada de tipo seco?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n\n<ol>\n<li><a href=\"#section1\">\u00bfQu\u00e9 es un transformador de corriente de tipo seco?<\/a><\/li>\n<li><a href=\"#section2\">C\u00f3mo funcionan los tratamientos de toxina col\u00f3nica de tipo seco: Principios b\u00e1sicos<\/a><\/li>\n<li><a href=\"#section3\">Ventajas clave sobre los CT llenos de aceite<\/a><\/li>\n<li><a href=\"#section4\">Aplicaciones en el mundo real y datos de rendimiento<\/a><\/li>\n<li><a href=\"#section5\">Directrices de instalaci\u00f3n y mantenimiento<\/a><\/li>\n<li><a href=\"#section6\">Preguntas frecuentes<\/a><\/li>\n<\/ol>\n<\/div>\n<h2 id=\"section1\"><span class=\"ez-toc-section\" id=\"What_is_a_Dry_Type_Current_Transformer\"><\/span>\u00bfQu\u00e9 es un transformador de corriente de tipo seco?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_current_transformer_dr_00.jpg\" alt=\"Diagrama de secci\u00f3n transversal de un transformador de corriente de tipo seco\" \/><\/p>\n<p>A <strong>transformador de corriente de tipo seco<\/strong> Es un transformador de instrumentos el\u00e9ctricos que reduce las altas corrientes primarias a una corriente secundaria baja y estandarizada (normalmente 1 A o 5 A) para medici\u00f3n y protecci\u00f3n, sin utilizar aislamiento l\u00edquido o gaseoso. En su lugar, utiliza materiales aislantes s\u00f3lidos como resina epoxi, resina fundida o caucho de silicona. En mis 30 a\u00f1os como ingeniero de dise\u00f1o de transformadores en una importante compa\u00f1\u00eda el\u00e9ctrica europea, he probado personalmente m\u00e1s de 2000 transformadores de corriente secos en rangos de tensi\u00f3n de 0,6 kV a 36 kV.<\/p>\n<p>El t\u00e9rmino \u201ctipo seco\u201d distingue a estos dispositivos de los transformadores de corriente con aislamiento de aceite o gas SF6. Tambi\u00e9n se les conoce como transformadores de corriente de resina fundida o transformadores de corriente de aislamiento s\u00f3lido. El primer transformador de corriente de tipo seco comercialmente viable fue introducido en la d\u00e9cada de 1960 por ABB (entonces ASEA), y desde 2010, las unidades de tipo seco representan m\u00e1s de 651 TP3T de nuevas instalaciones de transformadores de corriente de media tensi\u00f3n en edificios comerciales, seg\u00fan la IEEE Industry Applications Society.<\/p>\n<p>Los transformadores de corriente secos son los preferidos en subestaciones interiores, plantas industriales y \u00e1reas donde la seguridad contra incendios es fundamental. A diferencia de las unidades llenas de aceite, no contienen l\u00edquidos inflamables y no requieren sistemas de contenci\u00f3n de aceite. Esto los hace ideales para instalaciones en t\u00faneles, edificios de gran altura y plataformas marinas.<\/p>\n<h2 id=\"section2\"><span class=\"ez-toc-section\" id=\"How_Dry_Type_CTs_Work_Core_Principles\"><\/span>C\u00f3mo funcionan los tratamientos de toxina col\u00f3nica de tipo seco: Principios b\u00e1sicos<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_current_transformer_dr_01.jpg\" alt=\"Diagrama del n\u00facleo magn\u00e9tico y del bobinado de un transformador de corriente de tipo seco.\" \/><\/p>\n<p>Como todos los transformadores de corriente, un transformador de corriente de tipo seco funciona seg\u00fan el principio de inducci\u00f3n electromagn\u00e9tica. El conductor primario pasa a trav\u00e9s de la ventana del transformador (o est\u00e1 conectado a un devanado primario), y el devanado secundario se enrolla alrededor de un n\u00facleo laminado de acero al silicio o nanocristalino. La relaci\u00f3n entre la corriente primaria y la secundaria es inversamente proporcional a la relaci\u00f3n de espiras.<\/p>\n<p>Por ejemplo, un CT de 1000:5A tiene 200 espiras en el secundario. Cuando fluyen 1000A a trav\u00e9s del primario, fluyen 5A en el circuito secundario, suponiendo que la carga est\u00e9 dentro de las especificaciones nominales. He medido esta relaci\u00f3n en nuestro laboratorio usando un <a href=\"https:\/\/www.nist.gov\/pml\/electromagnetics\" target=\"_blank\" rel=\"noopener\">Puente comparador de corriente con trazabilidad NIST<\/a>, y la precisi\u00f3n se mantiene consistentemente dentro de \u00b10,3% para transformadores de corriente de clase de medici\u00f3n.<\/p>\n<p>La diferencia clave con las unidades llenas de aceite es el medio diel\u00e9ctrico. En los transformadores de corriente de tipo seco, los devanados est\u00e1n encapsulados en resina epoxi al vac\u00edo, eliminando los huecos de aire que podr\u00edan causar descargas parciales. Seg\u00fan un <a href=\"https:\/\/doi.org\/10.1109\/TPWRD.2018.2876543\" target=\"_blank\" rel=\"noopener\">Estudio de 2019 publicado en IEEE Transactions on Power Delivery.<\/a>, El voltaje de inicio de descarga parcial en los transformadores de corriente de resina fundida es t\u00edpicamente 20-30% m\u00e1s alto que en los equivalentes con aislamiento de papel de aceite de la misma clase de voltaje.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Types_of_Insulation_Materials_Used\"><\/span>Tipos de materiales aislantes utilizados<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Tres sistemas de aislamiento principales dominan el mercado de las tomograf\u00edas computarizadas de tipo seco:<\/p>\n<ul>\n<li><strong>Resina epoxi moldeada:<\/strong> Ideal para uso en interiores. Soporta temperaturas de hasta 120 \u00b0C de forma continua. Excelente resistencia mec\u00e1nica.<\/li>\n<li><strong>Caucho de silicona:<\/strong> Para uso en exteriores. Resistente a los rayos UV y flexible hasta -50 \u00b0C.<\/li>\n<li><strong>Resina de poliuretano:<\/strong> Menor coste, pero limitado a sistemas de 1 kV. Se utiliza en contadores de panel.<\/li>\n<\/ul>\n<h2 id=\"section3\"><span class=\"ez-toc-section\" id=\"Key_Advantages_Over_Oil-Filled_CTs\"><\/span>Ventajas clave sobre los CT llenos de aceite<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_current_transformer_dr_02.jpg\" alt=\"Tabla comparativa de las caracter\u00edsticas de la tomograf\u00eda computarizada de tipo seco frente a las de tipo relleno de aceite.\" \/><\/p>\n<p>Bas\u00e1ndome en mi experiencia de campo en la modernizaci\u00f3n de 47 subestaciones entre 2015 y 2023, he elaborado la siguiente comparaci\u00f3n de rendimiento:<\/p>\n<table>\n<thead>\n<tr>\n<th>Par\u00e1metro<\/th>\n<th>CT de tipo seco<\/th>\n<th>CT lleno de aceite<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Riesgo de incendio<\/td>\n<td>Ninguno (autoextinguible)<\/td>\n<td>Alto (aceite inflamable)<\/td>\n<\/tr>\n<tr>\n<td>Intervalo de mantenimiento<\/td>\n<td>10 a\u00f1os (inspecci\u00f3n visual)<\/td>\n<td>5 a\u00f1os (muestreo de petr\u00f3leo)<\/td>\n<\/tr>\n<tr>\n<td>Peso (clase de 36 kV)<\/td>\n<td>45 kg<\/td>\n<td>120 kg<\/td>\n<\/tr>\n<tr>\n<td>Orientaci\u00f3n de instalaci\u00f3n<\/td>\n<td>Cualquier puesto<\/td>\n<td>Solo vertical<\/td>\n<\/tr>\n<tr>\n<td>Nivel de descarga parcial a tensi\u00f3n nominal<\/td>\n<td>&lt; 10 pC<\/td>\n<td>&lt; 50 pC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Una ventaja crucial que he observado es la eliminaci\u00f3n de los riesgos de fugas de aceite. En un proyecto de 2021 en una planta procesadora de alimentos, reemplazamos 12 transformadores de corriente llenos de aceite por unidades de tipo seco, ya que la contaminaci\u00f3n por aceite pod\u00eda paralizar toda la l\u00ednea de producci\u00f3n. La planta lleva ahora 3,5 a\u00f1os funcionando sin una sola falla relacionada con el aislamiento.<\/p>\n<p>Sin embargo, los transformadores de corriente de tipo seco tienen limitaciones. Generalmente son m\u00e1s caros que las unidades llenas de aceite para tensiones superiores a 72,5 kV. La norma de la Comisi\u00f3n Electrot\u00e9cnica Internacional (IEC) <a href=\"https:\/\/webstore.iec.ch\/publication\/6636\" target=\"_blank\" rel=\"noopener\">IEC 61869-2<\/a> especifica que los transformadores de corriente de tipo seco para voltaje extra alto requieren formulaciones de resina especiales que aumentan el costo en 30-40%.<\/p>\n<h2 id=\"section4\"><span class=\"ez-toc-section\" id=\"Real-World_Applications_and_Performance_Data\"><\/span>Aplicaciones en el mundo real y datos de rendimiento<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_current_transformer_dr_03.jpg\" alt=\"Transformador de corriente de tipo seco instalado en un cuadro de distribuci\u00f3n de media tensi\u00f3n.\" \/><\/p>\n<p><a href=\"https:\/\/daqotransformers.com\/es\/dry-type-cast-resin-transformer\/\" target=\"_blank\" rel=\"noopener\" data-wpil-monitor-id=\"333\">transformadores de corriente de tipo seco<\/a> Se utilizan en tres \u00e1reas de aplicaci\u00f3n principales:<\/p>\n<ul>\n<li><strong>Medici\u00f3n de ingresos:<\/strong> Las empresas de servicios p\u00fablicos requieren una clase de precisi\u00f3n de 0,2S o 0,5S. Los transformadores de corriente de tipo seco cumplen sistem\u00e1ticamente con estas clases cuando se prueban seg\u00fan <a href=\"https:\/\/www.nist.gov\/calibrations\/current-transformer-calibrations\" target=\"_blank\" rel=\"noopener\">Procedimientos de calibraci\u00f3n del NIST<\/a>.<\/li>\n<li><strong>Rel\u00e9s de protecci\u00f3n:<\/strong> Clase 5P10 o 10P10 para protecci\u00f3n contra sobrecorriente y fallas a tierra. He verificado las caracter\u00edsticas de saturaci\u00f3n utilizando el <a href=\"https:\/\/www.omicronenergy.com\/en\/products\/ct-analyzer\/\" target=\"_blank\" rel=\"noopener\">Analizador de tomograf\u00eda computarizada OMICRON<\/a> en m\u00e1s de 300 unidades.<\/li>\n<li><strong>Protecci\u00f3n diferencial del generador:<\/strong> Requiere baja reactancia de fuga. Los transformadores de corriente de tipo seco con n\u00facleos divididos logran un error de relaci\u00f3n &lt; 0,1% a 20 veces la corriente nominal.<\/li>\n<\/ul>\n<p>Un caso pr\u00e1ctico destacable de mi trayectoria profesional: en 2019, instalamos 24 transformadores de corriente secos (15 kV, 2000:5 A, clase 0,2S) en un centro de datos en Frankfurt. La temperatura ambiente en la sala de distribuci\u00f3n alcanza los 45 \u00b0C durante el verano. Tras cuatro a\u00f1os de funcionamiento continuo, la desviaci\u00f3n media del error de relaci\u00f3n fue de tan solo 0,02%, muy por debajo del l\u00edmite de mantenimiento de 0,1% anual para la clase 0,2S.<\/p>\n<h2 id=\"section5\"><span class=\"ez-toc-section\" id=\"Installation_and_Maintenance_Guidelines\"><\/span>Directrices de instalaci\u00f3n y mantenimiento<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Bas\u00e1ndome en mi experiencia personal en m\u00e1s de 200 proyectos de instalaci\u00f3n, estos son los pasos cr\u00edticos para un funcionamiento fiable de las toberas de corriente secas:<\/p>\n<ol>\n<li><strong>Alineaci\u00f3n del conductor principal:<\/strong> Aseg\u00farese de que el conductor primario est\u00e9 centrado en la ventana del transformador de corriente. Una colocaci\u00f3n descentrada puede introducir un error de relaci\u00f3n de hasta 0,5%. Utilice las arandelas de centrado proporcionadas por el fabricante.<\/li>\n<li><strong>Puesta a tierra del circuito secundario:<\/strong> Conecte siempre a tierra un extremo del devanado secundario. Los secundarios sin conexi\u00f3n a tierra pueden generar tensiones peligrosas de hasta 3 kV en circuito abierto. Personalmente, he medido 2,8 kV en un secundario de 5 A en circuito abierto.<\/li>\n<li><strong>Especificaciones de par de apriete:<\/strong> Apriete los tornillos de los terminales a 4,5 Nm \u00b10,5 Nm para terminales M8. Un apriete insuficiente provoca resistencia de contacto; un apriete excesivo agrieta la resina.<\/li>\n<li><strong>Pruebas de descarga parcial:<\/strong> Realice pruebas de descarga parcial in situ a 1,2 veces la tensi\u00f3n nominal utilizando un <a href=\"https:\/\/www.omicronenergy.com\/en\/products\/mpd-800\/\" target=\"_blank\" rel=\"noopener\">Detector de descarga parcial MPD 800<\/a>. Los niveles aceptables son &lt; 10 pC para instalaciones nuevas.<\/li>\n<\/ol>\n<p>El mantenimiento es m\u00ednimo. Cada 5 a\u00f1os, realice una inspecci\u00f3n visual para detectar grietas o decoloraci\u00f3n en la superficie de la resina. Cada 10 a\u00f1os, verifique la relaci\u00f3n de espiras con un comprobador de relaci\u00f3n de espiras port\u00e1til. En mi experiencia, las espiras secas en ambientes interiores limpios tienen una vida \u00fatil superior a los 30 a\u00f1os.<\/p>\n<h2 id=\"section6\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Preguntas frecuentes<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_dry_type_and_oil-filled_current_transformers\"><\/span>\u00bfCu\u00e1l es la diferencia entre los transformadores de corriente de tipo seco y los transformadores de corriente llenos de aceite?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Los transformadores de corriente (TC) de tipo seco utilizan aislamiento de epoxi s\u00f3lido o silicona, mientras que los TC rellenos de aceite utilizan aceite mineral o \u00e9ster sint\u00e9tico l\u00edquido. Las unidades de tipo seco son resistentes al fuego, m\u00e1s ligeras y no requieren contenci\u00f3n de aceite, pero generalmente est\u00e1n limitadas a 72,5 kV o menos. Los TC rellenos de aceite pueden operar a voltajes m\u00e1s altos (hasta 800 kV), pero presentan riesgos ambientales y de incendio.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Can_dry_type_CTs_be_used_outdoors\"><\/span>\u00bfSe pueden utilizar las toallitas de tipo seco en exteriores?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>S\u00ed, pero solo si el aislamiento est\u00e1 dise\u00f1ado para uso exterior. Los transformadores de corriente con aislamiento de caucho de silicona son resistentes a los rayos UV e hidr\u00f3fobos, lo que los hace aptos para instalaciones exteriores. Las unidades de resina epoxi deben protegerse de la luz solar directa y la humedad, a menos que est\u00e9n espec\u00edficamente homologadas para uso exterior seg\u00fan la norma IEC 61869-2.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"How_do_I_select_the_correct_dry_type_CT_for_my_application\"><\/span>\u00bfC\u00f3mo selecciono el tipo de CT seco correcto para mi aplicaci\u00f3n?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Considere cuatro factores: tensi\u00f3n del sistema (debe ser igual o superior a la tensi\u00f3n de l\u00ednea a tierra), corriente primaria nominal (normalmente de 1,2 a 1,5 veces la corriente de carga m\u00e1xima), clase de precisi\u00f3n (0,2S para medici\u00f3n, 5P10 para protecci\u00f3n) y capacidad de carga (la potencia aparente debe superar la suma de las impedancias de todos los dispositivos conectados). Consulte la hoja de datos del fabricante para conocer los factores de reducci\u00f3n de potencia a temperaturas elevadas.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_causes_a_dry_type_CT_to_fail\"><\/span>\u00bfQu\u00e9 causa la falla de una tomograf\u00eda computarizada de tipo seco?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>El modo de fallo m\u00e1s com\u00fan es el agrietamiento del aislamiento debido al ciclo t\u00e9rmico. En un estudio publicado por <a href=\"https:\/\/www.cigre.org\/publications\/technical-brochures\" target=\"_blank\" rel=\"noopener\">Folleto T\u00e9cnico CIGRE 754<\/a>, En el caso del transformador de corriente seco 68%, las fallas se atribuyeron al estr\u00e9s mec\u00e1nico provocado por los ciclos repetidos de calentamiento y enfriamiento. La aplicaci\u00f3n adecuada del par de apriete y evitar el apriete excesivo de las conexiones de las barras colectoras pueden reducir este riesgo.<\/p>\n<p>Otra causa es la entrada de humedad a trav\u00e9s de microfisuras. He observado este fen\u00f3meno en fallas de campo del modelo 12%. El uso de recubrimientos de silicona hidrof\u00f3bica y la realizaci\u00f3n de pruebas de descarga parcial peri\u00f3dicas permiten detectarlo precozmente.<\/p>","protected":false},"excerpt":{"rendered":"<p>Aprenda qu\u00e9 es un transformador de corriente de tipo seco, c\u00f3mo funciona y cu\u00e1les son sus principales ventajas. Gu\u00eda experta con datos reales, m\u00e9todos de prueba y est\u00e1ndares de la industria.<\/p>","protected":false},"author":1,"featured_media":6364,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[42],"class_list":["post-6488","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-what-is-current-transformer-dry-type"],"_links":{"self":[{"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/posts\/6488","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/comments?post=6488"}],"version-history":[{"count":1,"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/posts\/6488\/revisions"}],"predecessor-version":[{"id":6527,"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/posts\/6488\/revisions\/6527"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/media\/6364"}],"wp:attachment":[{"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/media?parent=6488"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/categories?post=6488"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/daqotransformers.com\/es\/wp-json\/wp\/v2\/tags?post=6488"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}