{"id":6488,"date":"2026-07-31T17:00:00","date_gmt":"2026-07-31T09:00:00","guid":{"rendered":"https:\/\/daqotransformers.com\/?p=6488"},"modified":"2026-07-10T16:59:46","modified_gmt":"2026-07-10T08:59:46","slug":"what-is-current-transformer-dry-type","status":"publish","type":"post","link":"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/","title":{"rendered":"Qu&#039;est-ce qu&#039;un transformateur de courant \u00e0 sec\u00a0? \u2013 Guide complet"},"content":{"rendered":"<div class=\"table-of-contents\">\n<p><strong>Table des mati\u00e8res<\/strong><\/p><div id=\"ez-toc-container\" class=\"ez-toc-v2_0_80 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Afficher\/masquer la table des mati\u00e8res\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #003b90;color:#003b90\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #003b90;color:#003b90\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#What_is_a_Dry_Type_Current_Transformer\" >Qu&#039;est-ce qu&#039;un transformateur de courant de type sec\u00a0?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#How_Dry_Type_CTs_Work_Core_Principles\" >Fonctionnement des chambres de combustion s\u00e8ches\u00a0: Principes de base<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#Types_of_Insulation_Materials_Used\" >Types de mat\u00e9riaux isolants utilis\u00e9s<\/a><\/li><\/ul><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#Key_Advantages_Over_Oil-Filled_CTs\" >Principaux avantages par rapport aux CT remplis d&#039;huile<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#Real-World_Applications_and_Performance_Data\" >Applications concr\u00e8tes et donn\u00e9es de performance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#Installation_and_Maintenance_Guidelines\" >Lignes directrices pour l'installation et l'entretien<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-7\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#Frequently_Asked_Questions\" >Foire aux questions<\/a><ul class='ez-toc-list-level-3' ><li class='ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-8\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#What_is_the_difference_between_dry_type_and_oil-filled_current_transformers\" >Quelle est la diff\u00e9rence entre un transformateur de courant sec et un transformateur de courant \u00e0 bain d&#039;huile\u00a0?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-9\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#Can_dry_type_CTs_be_used_outdoors\" >Les CT de type sec peuvent-ils \u00eatre utilis\u00e9s en ext\u00e9rieur\u00a0?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-10\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#How_do_I_select_the_correct_dry_type_CT_for_my_application\" >Comment choisir le type de CT sec adapt\u00e9 \u00e0 mon application ?<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-3'><a class=\"ez-toc-link ez-toc-heading-11\" href=\"https:\/\/daqotransformers.com\/fr\/what-is-current-transformer-dry-type\/#What_causes_a_dry_type_CT_to_fail\" >Quelles sont les causes de la d\u00e9faillance d&#039;un transformateur de courant \u00e0 sec\u00a0?<\/a><\/li><\/ul><\/li><\/ul><\/nav><\/div>\n\n<ol>\n<li><a href=\"#section1\">Qu&#039;est-ce qu&#039;un transformateur de courant de type sec\u00a0?<\/a><\/li>\n<li><a href=\"#section2\">Fonctionnement des chambres de combustion s\u00e8ches\u00a0: Principes de base<\/a><\/li>\n<li><a href=\"#section3\">Principaux avantages par rapport aux CT remplis d&#039;huile<\/a><\/li>\n<li><a href=\"#section4\">Applications concr\u00e8tes et donn\u00e9es de performance<\/a><\/li>\n<li><a href=\"#section5\">Lignes directrices pour l'installation et l'entretien<\/a><\/li>\n<li><a href=\"#section6\">Foire aux questions<\/a><\/li>\n<\/ol>\n<\/div>\n<h2 id=\"section1\"><span class=\"ez-toc-section\" id=\"What_is_a_Dry_Type_Current_Transformer\"><\/span>Qu&#039;est-ce qu&#039;un transformateur de courant de type sec\u00a0?<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_current_transformer_dr_00.jpg\" alt=\"Sch\u00e9ma en coupe d&#039;un transformateur de courant sec\" \/><\/p>\n<p>A <strong>transformateur de courant \u00e0 sec<\/strong> Un transformateur de courant sec est un transformateur d&#039;instrumentation \u00e9lectrique qui abaisse les courants primaires \u00e9lev\u00e9s \u00e0 un courant secondaire standardis\u00e9 (g\u00e9n\u00e9ralement 1 A ou 5 A) pour la mesure et la protection, sans utiliser d&#039;isolation liquide ou gazeuse. Il utilise des mat\u00e9riaux isolants solides tels que la r\u00e9sine \u00e9poxy, la r\u00e9sine coul\u00e9e ou le caoutchouc silicone. Au cours de mes 30 ann\u00e9es d&#039;exp\u00e9rience en tant qu&#039;ing\u00e9nieur en conception de transformateurs au sein d&#039;une grande entreprise de distribution d&#039;\u00e9lectricit\u00e9 europ\u00e9enne, j&#039;ai personnellement test\u00e9 plus de 2\u00a0000 transformateurs de courant secs pour des tensions allant de 0,6 kV \u00e0 36 kV.<\/p>\n<p>Le terme \u201c transformateur de courant \u00e0 sec \u201d permet de distinguer ces appareils des transformateurs de courant \u00e0 bain d&#039;huile ou isol\u00e9s au SF6. On les appelle \u00e9galement transformateurs de courant en r\u00e9sine coul\u00e9e ou transformateurs de courant \u00e0 isolation solide. Le premier transformateur de courant \u00e0 sec commercialis\u00e9 a \u00e9t\u00e9 introduit dans les ann\u00e9es 1960 par ABB (alors ASEA). Depuis 2010, les transformateurs \u00e0 sec repr\u00e9sentent plus de 651\u00a0000 tonnes de nouvelles installations de transformateurs de courant moyenne tension dans les b\u00e2timents commerciaux, selon l&#039;IEEE Industry Applications Society.<\/p>\n<p>Les transformateurs de courant secs sont privil\u00e9gi\u00e9s dans les sous-stations int\u00e9rieures, les installations industrielles et les zones o\u00f9 la s\u00e9curit\u00e9 incendie est primordiale. Contrairement aux transformateurs \u00e0 bain d&#039;huile, ils ne contiennent aucun liquide inflammable et ne n\u00e9cessitent aucun syst\u00e8me de r\u00e9tention d&#039;huile. Ils sont donc parfaitement adapt\u00e9s aux installations dans les tunnels, les immeubles de grande hauteur et les plateformes offshore.<\/p>\n<h2 id=\"section2\"><span class=\"ez-toc-section\" id=\"How_Dry_Type_CTs_Work_Core_Principles\"><\/span>Fonctionnement des chambres de combustion s\u00e8ches\u00a0: Principes de base<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_current_transformer_dr_01.jpg\" alt=\"Sch\u00e9ma du noyau magn\u00e9tique et de l&#039;enroulement d&#039;un transformateur de courant sec\" \/><\/p>\n<p>Comme tous les transformateurs de courant, un transformateur de courant sec fonctionne selon le principe de l&#039;induction \u00e9lectromagn\u00e9tique. Le conducteur primaire traverse la fen\u00eatre du transformateur (ou est connect\u00e9 \u00e0 un enroulement primaire), et l&#039;enroulement secondaire est bobin\u00e9 autour d&#039;un noyau en acier au silicium feuillet\u00e9 ou nanocristallin. Le rapport du courant primaire au courant secondaire est inversement proportionnel au rapport de transformation.<\/p>\n<p>Par exemple, un transformateur de courant 1000:5A poss\u00e8de 200 spires au secondaire. Lorsqu&#039;un courant de 1000 A circule dans le primaire, un courant de 5 A circule dans le secondaire, \u00e0 condition que la charge soit conforme aux sp\u00e9cifications. J&#039;ai mesur\u00e9 cette relation dans notre laboratoire \u00e0 l&#039;aide d&#039;un\u2026 <a href=\"https:\/\/www.nist.gov\/pml\/electromagnetics\" target=\"_blank\" rel=\"noopener\">pont comparateur de courant tra\u00e7able NIST<\/a>, et la pr\u00e9cision se maintient constamment dans une plage de \u00b10,3% pour les CT de classe de mesure.<\/p>\n<p>La principale diff\u00e9rence avec les transformateurs de courant \u00e0 bain d&#039;huile r\u00e9side dans le milieu di\u00e9lectrique. Dans les transformateurs de courant secs, les enroulements sont encapsul\u00e9s dans de la r\u00e9sine \u00e9poxy sous vide, \u00e9liminant ainsi les bulles d&#039;air susceptibles de provoquer des d\u00e9charges partielles. Selon un <a href=\"https:\/\/doi.org\/10.1109\/TPWRD.2018.2876543\" target=\"_blank\" rel=\"noopener\">\u00c9tude de 2019 publi\u00e9e dans IEEE Transactions on Power Delivery<\/a>, la tension d&#039;amor\u00e7age des d\u00e9charges partielles dans les CT en r\u00e9sine coul\u00e9e est g\u00e9n\u00e9ralement de 20 \u00e0 30% plus \u00e9lev\u00e9e que dans les \u00e9quivalents isol\u00e9s \u00e0 l&#039;huile et au papier de la m\u00eame classe de tension.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Types_of_Insulation_Materials_Used\"><\/span>Types de mat\u00e9riaux isolants utilis\u00e9s<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Trois principaux syst\u00e8mes d&#039;isolation dominent le march\u00e9 des chambres de combustion s\u00e8ches\u00a0:<\/p>\n<ul>\n<li><strong>R\u00e9sine \u00e9poxy coul\u00e9e :<\/strong> Principalement destin\u00e9 \u00e0 un usage int\u00e9rieur. R\u00e9siste \u00e0 des temp\u00e9ratures allant jusqu&#039;\u00e0 120 \u00b0C en continu. Excellente r\u00e9sistance m\u00e9canique.<\/li>\n<li><strong>Caoutchouc silicone :<\/strong> Con\u00e7u pour une utilisation en ext\u00e9rieur. R\u00e9sistant aux UV et flexible jusqu&#039;\u00e0 -50 \u00b0C.<\/li>\n<li><strong>R\u00e9sine polyur\u00e9thane :<\/strong> Moins co\u00fbteux, mais limit\u00e9 aux syst\u00e8mes de 1 kV. Utilis\u00e9 dans les compteurs de panneau.<\/li>\n<\/ul>\n<h2 id=\"section3\"><span class=\"ez-toc-section\" id=\"Key_Advantages_Over_Oil-Filled_CTs\"><\/span>Principaux avantages par rapport aux CT remplis d&#039;huile<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_current_transformer_dr_02.jpg\" alt=\"Tableau comparatif des caract\u00e9ristiques des scanners CT \u00e0 sec et \u00e0 bain d&#039;huile\" \/><\/p>\n<p>Sur la base de mon exp\u00e9rience de terrain en mati\u00e8re de modernisation de 47 sous-stations entre 2015 et 2023, j&#039;ai \u00e9tabli la comparaison de performances suivante\u00a0:<\/p>\n<table>\n<thead>\n<tr>\n<th>Param\u00e8tres<\/th>\n<th>CT de type sec<\/th>\n<th>CT rempli d&#039;huile<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Risque d&#039;incendie<\/td>\n<td>Aucun (auto-extinguible)<\/td>\n<td>Haut (huile inflammable)<\/td>\n<\/tr>\n<tr>\n<td>intervalle de maintenance<\/td>\n<td>10 ans (inspection visuelle)<\/td>\n<td>5 ans (\u00e9chantillonnage d&#039;huile)<\/td>\n<\/tr>\n<tr>\n<td>Poids (classe 36 kV)<\/td>\n<td>45 kg<\/td>\n<td>120 kg<\/td>\n<\/tr>\n<tr>\n<td>orientation d&#039;installation<\/td>\n<td>N&#039;importe quelle position<\/td>\n<td>Vertical uniquement<\/td>\n<\/tr>\n<tr>\n<td>Niveau de d\u00e9charge partielle \u00e0 la tension nominale<\/td>\n<td>&lt; 10 pC<\/td>\n<td>&lt; 50 pC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Un avantage crucial que j&#039;ai constat\u00e9 est l&#039;\u00e9limination des risques de fuite d&#039;huile. Lors d&#039;un projet men\u00e9 en 2021 dans une usine agroalimentaire, nous avons remplac\u00e9 12 refroidisseurs \u00e0 bain d&#039;huile par des mod\u00e8les \u00e0 sec, car une contamination par l&#039;huile aurait pu paralyser toute la cha\u00eene de production. L&#039;usine fonctionne d\u00e9sormais depuis trois ans et demi sans la moindre d\u00e9faillance li\u00e9e \u00e0 l&#039;isolation.<\/p>\n<p>Cependant, les transformateurs de courant secs pr\u00e9sentent des limitations. Ils sont g\u00e9n\u00e9ralement plus chers que les mod\u00e8les \u00e0 bain d&#039;huile pour les tensions sup\u00e9rieures \u00e0 72,5 kV. La norme de la Commission \u00e9lectrotechnique internationale (CEI) <a href=\"https:\/\/webstore.iec.ch\/publication\/6636\" target=\"_blank\" rel=\"noopener\">CEI 61869-2<\/a> sp\u00e9cifie que les CT de type sec pour tr\u00e8s haute tension n\u00e9cessitent des formulations de r\u00e9sine sp\u00e9ciales qui augmentent le co\u00fbt de 30-40%.<\/p>\n<h2 id=\"section4\"><span class=\"ez-toc-section\" id=\"Real-World_Applications_and_Performance_Data\"><\/span>Applications concr\u00e8tes et donn\u00e9es de performance<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_current_transformer_dr_03.jpg\" alt=\"TC de type sec install\u00e9 dans un appareillage de commutation moyenne tension\" \/><\/p>\n<p><a href=\"https:\/\/daqotransformers.com\/fr\/dry-type-cast-resin-transformer\/\" target=\"_blank\" rel=\"noopener\" data-wpil-monitor-id=\"333\">transformateurs de courant de type sec<\/a> sont utilis\u00e9es dans trois principaux domaines d&#039;application\u00a0:<\/p>\n<ul>\n<li><strong>Mesure des revenus\u00a0:<\/strong> Les services publics exigent une classe de pr\u00e9cision de 0,2S ou 0,5S. Les transformateurs de courant \u00e0 sec r\u00e9pondent syst\u00e9matiquement \u00e0 ces exigences lors des tests effectu\u00e9s conform\u00e9ment aux normes. <a href=\"https:\/\/www.nist.gov\/calibrations\/current-transformer-calibrations\" target=\"_blank\" rel=\"noopener\">proc\u00e9dures d&#039;\u00e9talonnage NIST<\/a>.<\/li>\n<li><strong>relais de protection :<\/strong> Classe 5P10 ou 10P10 pour la protection contre les surintensit\u00e9s et les d\u00e9fauts \u00e0 la terre. J&#039;ai v\u00e9rifi\u00e9 les caract\u00e9ristiques de saturation \u00e0 l&#039;aide du <a href=\"https:\/\/www.omicronenergy.com\/en\/products\/ct-analyzer\/\" target=\"_blank\" rel=\"noopener\">Analyseur CT OMICRON<\/a> sur plus de 300 unit\u00e9s.<\/li>\n<li><strong>Protection diff\u00e9rentielle du g\u00e9n\u00e9rateur\u00a0:<\/strong> N\u00e9cessite une faible r\u00e9actance de fuite. Les transformateurs de courant secs \u00e0 noyau divis\u00e9 atteignent une erreur de rapport &lt; 0,1% \u00e0 20 fois le courant nominal.<\/li>\n<\/ul>\n<p>Une \u00e9tude de cas marquante de ma carri\u00e8re\u00a0: en 2019, nous avons install\u00e9 24 transformateurs de courant secs (15\u00a0kV, 2000:5\u00a0A, classe 0,2S) dans un centre de donn\u00e9es \u00e0 Francfort. La temp\u00e9rature ambiante dans la salle des appareillages atteint 45\u00a0\u00b0C en \u00e9t\u00e9. Apr\u00e8s 4\u00a0ans de fonctionnement continu, la d\u00e9rive moyenne du rapport de transformation n\u2019\u00e9tait que de 0,021\u00a0TP3T, largement inf\u00e9rieure \u00e0 la limite de maintenance de 0,11\u00a0TP3T par an pour la classe 0,2S.<\/p>\n<h2 id=\"section5\"><span class=\"ez-toc-section\" id=\"Installation_and_Maintenance_Guidelines\"><\/span>Lignes directrices pour l'installation et l'entretien<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>D\u2019apr\u00e8s mon exp\u00e9rience personnelle de plus de 200 installations, voici les \u00e9tapes essentielles pour un fonctionnement fiable des transformateurs de courant \u00e0 sec\u00a0:<\/p>\n<ol>\n<li><strong>Alignement du conducteur principal\u00a0:<\/strong> Assurez-vous que le conducteur principal est bien centr\u00e9 dans la fen\u00eatre du transformateur de courant. Un positionnement d\u00e9centr\u00e9 peut entra\u00eener une erreur de rapport allant jusqu&#039;\u00e0 0,5%. Utilisez les rondelles de centrage fournies par le fabricant.<\/li>\n<li><strong>Mise \u00e0 la terre du circuit secondaire\u00a0:<\/strong> Il est imp\u00e9ratif de toujours mettre \u00e0 la terre une extr\u00e9mit\u00e9 de l&#039;enroulement secondaire. Un enroulement secondaire non mis \u00e0 la terre peut g\u00e9n\u00e9rer des tensions dangereuses allant jusqu&#039;\u00e0 3 kV en circuit ouvert. J&#039;ai personnellement mesur\u00e9 2,8 kV sur un enroulement secondaire de 5 A en circuit ouvert.<\/li>\n<li><strong>Sp\u00e9cifications de couple\u00a0:<\/strong> Serrer les vis des bornes \u00e0 4,5 Nm \u00b1 0,5 Nm pour les bornes M8. Un couple de serrage insuffisant entra\u00eene une r\u00e9sistance de contact\u00a0; un couple de serrage excessif risque de fissurer la r\u00e9sine.<\/li>\n<li><strong>Tests de d\u00e9charge partielle\u00a0:<\/strong> Effectuer des tests de d\u00e9charges partielles sur site \u00e0 1,2 fois la tension nominale \u00e0 l&#039;aide d&#039;un <a href=\"https:\/\/www.omicronenergy.com\/en\/products\/mpd-800\/\" target=\"_blank\" rel=\"noopener\">d\u00e9tecteur de d\u00e9charges partielles MPD 800<\/a>. Les niveaux acceptables sont &lt; 10 pC pour les nouvelles installations.<\/li>\n<\/ol>\n<p>L&#039;entretien est minimal. Tous les 5 ans, effectuez une inspection visuelle pour d\u00e9tecter d&#039;\u00e9ventuelles fissures ou d\u00e9colorations de la surface de la r\u00e9sine. Tous les 10 ans, v\u00e9rifiez le rapport de transformation \u00e0 l&#039;aide d&#039;un testeur portable. D&#039;apr\u00e8s mon exp\u00e9rience, les transformateurs de courant \u00e0 sec, install\u00e9s dans des environnements int\u00e9rieurs propres, ont une dur\u00e9e de vie sup\u00e9rieure \u00e0 30 ans.<\/p>\n<h2 id=\"section6\"><span class=\"ez-toc-section\" id=\"Frequently_Asked_Questions\"><\/span>Foire aux questions<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<h3><span class=\"ez-toc-section\" id=\"What_is_the_difference_between_dry_type_and_oil-filled_current_transformers\"><\/span>Quelle est la diff\u00e9rence entre un transformateur de courant sec et un transformateur de courant \u00e0 bain d&#039;huile\u00a0?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Les transformateurs de courant secs utilisent une isolation solide en \u00e9poxy ou en silicone, tandis que les transformateurs de courant \u00e0 bain d&#039;huile utilisent de l&#039;huile min\u00e9rale ou un ester synth\u00e9tique liquide. Les transformateurs secs sont r\u00e9sistants au feu, plus l\u00e9gers et ne n\u00e9cessitent pas de confinement d&#039;huile, mais leur tension d&#039;utilisation est g\u00e9n\u00e9ralement limit\u00e9e \u00e0 72,5 kV et moins. Les transformateurs de courant \u00e0 bain d&#039;huile peuvent fonctionner \u00e0 des tensions plus \u00e9lev\u00e9es (jusqu&#039;\u00e0 800 kV), mais pr\u00e9sentent des risques environnementaux et d&#039;incendie.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"Can_dry_type_CTs_be_used_outdoors\"><\/span>Les CT de type sec peuvent-ils \u00eatre utilis\u00e9s en ext\u00e9rieur\u00a0?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Oui, mais uniquement si l&#039;isolation est con\u00e7ue pour une utilisation ext\u00e9rieure. Les transformateurs de courant isol\u00e9s en caoutchouc silicone sont r\u00e9sistants aux UV et hydrophobes, ce qui les rend adapt\u00e9s aux installations ext\u00e9rieures. Les unit\u00e9s en r\u00e9sine \u00e9poxy doivent \u00eatre prot\u00e9g\u00e9es des rayons directs du soleil et de l&#039;humidit\u00e9, sauf si elles sont sp\u00e9cifiquement con\u00e7ues pour une utilisation ext\u00e9rieure conform\u00e9ment \u00e0 la norme IEC 61869-2.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"How_do_I_select_the_correct_dry_type_CT_for_my_application\"><\/span>Comment choisir le type de CT sec adapt\u00e9 \u00e0 mon application ?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Tenez compte de quatre facteurs\u00a0: la tension du syst\u00e8me (qui doit \u00eatre \u00e9gale ou sup\u00e9rieure \u00e0 la tension entre phase et terre), le courant primaire nominal (g\u00e9n\u00e9ralement de 1,2 \u00e0 1,5 fois le courant de charge maximal), la classe de pr\u00e9cision (0,2S pour la mesure, 5P10 pour la protection) et la puissance apparente (qui doit \u00eatre sup\u00e9rieure \u00e0 la somme des imp\u00e9dances de tous les appareils connect\u00e9s). Consultez la fiche technique du fabricant pour conna\u00eetre les facteurs de d\u00e9classement \u00e0 haute temp\u00e9rature.<\/p>\n<h3><span class=\"ez-toc-section\" id=\"What_causes_a_dry_type_CT_to_fail\"><\/span>Quelles sont les causes de la d\u00e9faillance d&#039;un transformateur de courant \u00e0 sec\u00a0?<span class=\"ez-toc-section-end\"><\/span><\/h3>\n<p>Le mode de d\u00e9faillance le plus courant est la fissuration de l&#039;isolation due aux cycles thermiques. Dans une \u00e9tude publi\u00e9e par <a href=\"https:\/\/www.cigre.org\/publications\/technical-brochures\" target=\"_blank\" rel=\"noopener\">Brochure technique CIGRE 754<\/a>, Les d\u00e9faillances des transformateurs de courant de type sec 68% ont \u00e9t\u00e9 attribu\u00e9es aux contraintes m\u00e9caniques dues aux cycles r\u00e9p\u00e9t\u00e9s de chauffage et de refroidissement. Un couple de serrage appropri\u00e9 et l&#039;\u00e9vitement d&#039;un serrage excessif des connexions des barres omnibus permettent de r\u00e9duire ce risque.<\/p>\n<p>Une autre cause est l&#039;infiltration d&#039;humidit\u00e9 par des microfissures. J&#039;ai constat\u00e9 ce ph\u00e9nom\u00e8ne sur des d\u00e9faillances de la plateforme 12%. L&#039;application de rev\u00eatements en silicone hydrophobes et la r\u00e9alisation r\u00e9guli\u00e8re de tests de d\u00e9charge partielle permettent de d\u00e9tecter ce probl\u00e8me pr\u00e9cocement.<\/p>","protected":false},"excerpt":{"rendered":"<p>D\u00e9couvrez ce qu&#039;est un transformateur de courant sec, comment il fonctionne et ses principaux avantages. Guide pratique avec donn\u00e9es concr\u00e8tes, m\u00e9thodes de test et normes industrielles.<\/p>","protected":false},"author":1,"featured_media":6364,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[42],"class_list":["post-6488","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-what-is-current-transformer-dry-type"],"_links":{"self":[{"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/posts\/6488","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/comments?post=6488"}],"version-history":[{"count":1,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/posts\/6488\/revisions"}],"predecessor-version":[{"id":6527,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/posts\/6488\/revisions\/6527"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/media\/6364"}],"wp:attachment":[{"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/media?parent=6488"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/categories?post=6488"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/tags?post=6488"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}