{"id":6491,"date":"2026-08-06T23:00:00","date_gmt":"2026-08-06T15:00:00","guid":{"rendered":"https:\/\/daqotransformers.com\/?p=6491"},"modified":"2026-08-06T00:00:00","modified_gmt":"2026-08-05T16:00:00","slug":"dry-type-vs-wet-type-transformers-difference","status":"publish","type":"post","link":"https:\/\/daqotransformers.com\/fr\/dry-type-vs-wet-type-transformers-difference\/","title":{"rendered":"Transformateurs \u00e0 sec et \u00e0 bain d&#039;huile\u00a0: principales diff\u00e9rences expliqu\u00e9es | Guide d&#039;expert"},"content":{"rendered":"<div class=\"toc\">\n<h2><span class=\"ez-toc-section\" id=\"Table_of_Contents\"><\/span>Table des mati\u00e8res<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<ul>\n<li><a href=\"#section1\">1. M\u00e9canisme de refroidissement du noyau : la diff\u00e9rence fondamentale<\/a><\/li>\n<li><a href=\"#section2\">2. S\u00e9curit\u00e9, risques d&#039;incendie et impact environnemental<\/a><\/li>\n<li><a href=\"#section3\">3. Indicateurs de performance : efficacit\u00e9, dur\u00e9e de vie et maintenance<\/a><\/li>\n<li><a href=\"#section4\">4. Analyse des co\u00fbts : Investissement initial vs Co\u00fbt total de possession<\/a><\/li>\n<li><a href=\"#section5\">5. Comment choisir\u00a0: Matrice de d\u00e9cision d\u2019application<\/a><\/li>\n<\/ul>\n<\/div>\n<h2 id=\"section1\"><span class=\"ez-toc-section\" id=\"1_Core_Cooling_Mechanism_The_Fundamental_Difference\"><\/span>1. M\u00e9canisme de refroidissement du noyau : la diff\u00e9rence fondamentale<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_the_difference_between_00.jpg\" alt=\"Sch\u00e9ma en coupe comparant les syst\u00e8mes de refroidissement internes des transformateurs de type sec et de type humide\" \/><\/p><div id=\"ez-toc-container\" class=\"ez-toc-v2_0_80 counter-hierarchy ez-toc-counter ez-toc-custom ez-toc-container-direction\">\n<div class=\"ez-toc-title-container\">\n<p class=\"ez-toc-title\" style=\"cursor:inherit\">Table des mati\u00e8res<\/p>\n<span class=\"ez-toc-title-toggle\"><a href=\"#\" class=\"ez-toc-pull-right ez-toc-btn ez-toc-btn-xs ez-toc-btn-default ez-toc-toggle\" aria-label=\"Afficher\/masquer la table des mati\u00e8res\"><span class=\"ez-toc-js-icon-con\"><span class=\"\"><span class=\"eztoc-hide\" style=\"display:none;\">Toggle<\/span><span class=\"ez-toc-icon-toggle-span\"><svg style=\"fill: #003b90;color:#003b90\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" class=\"list-377408\" width=\"20px\" height=\"20px\" viewbox=\"0 0 24 24\" fill=\"none\"><path d=\"M6 6H4v2h2V6zm14 0H8v2h12V6zM4 11h2v2H4v-2zm16 0H8v2h12v-2zM4 16h2v2H4v-2zm16 0H8v2h12v-2z\" fill=\"currentColor\"><\/path><\/svg><svg style=\"fill: #003b90;color:#003b90\" class=\"arrow-unsorted-368013\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"10px\" height=\"10px\" viewbox=\"0 0 24 24\" version=\"1.2\" baseprofile=\"tiny\"><path d=\"M18.2 9.3l-6.2-6.3-6.2 6.3c-.2.2-.3.4-.3.7s.1.5.3.7c.2.2.4.3.7.3h11c.3 0 .5-.1.7-.3.2-.2.3-.5.3-.7s-.1-.5-.3-.7zM5.8 14.7l6.2 6.3 6.2-6.3c.2-.2.3-.5.3-.7s-.1-.5-.3-.7c-.2-.2-.4-.3-.7-.3h-11c-.3 0-.5.1-.7.3-.2.2-.3.5-.3.7s.1.5.3.7z\"\/><\/svg><\/span><\/span><\/span><\/a><\/span><\/div>\n<nav><ul class='ez-toc-list ez-toc-list-level-1' ><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-1\" href=\"https:\/\/daqotransformers.com\/fr\/dry-type-vs-wet-type-transformers-difference\/#Table_of_Contents\" >Table des mati\u00e8res<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-2\" href=\"https:\/\/daqotransformers.com\/fr\/dry-type-vs-wet-type-transformers-difference\/#1_Core_Cooling_Mechanism_The_Fundamental_Difference\" >1. M\u00e9canisme de refroidissement du noyau : la diff\u00e9rence fondamentale<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-3\" href=\"https:\/\/daqotransformers.com\/fr\/dry-type-vs-wet-type-transformers-difference\/#2_Safety_Fire_Risk_and_Environmental_Impact\" >2. S\u00e9curit\u00e9, risques d&#039;incendie et impact environnemental<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-4\" href=\"https:\/\/daqotransformers.com\/fr\/dry-type-vs-wet-type-transformers-difference\/#3_Performance_Metrics_Efficiency_Lifespan_and_Maintenance\" >3. Indicateurs de performance : efficacit\u00e9, dur\u00e9e de vie et maintenance<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-5\" href=\"https:\/\/daqotransformers.com\/fr\/dry-type-vs-wet-type-transformers-difference\/#4_Cost_Analysis_Initial_Investment_vs_Total_Cost_of_Ownership\" >4. Analyse des co\u00fbts : Investissement initial vs Co\u00fbt total de possession<\/a><\/li><li class='ez-toc-page-1 ez-toc-heading-level-2'><a class=\"ez-toc-link ez-toc-heading-6\" href=\"https:\/\/daqotransformers.com\/fr\/dry-type-vs-wet-type-transformers-difference\/#5_How_to_Choose_Application_Decision_Matrix\" >5. Comment choisir\u00a0: Matrice de d\u00e9cision d\u2019application<\/a><\/li><\/ul><\/nav><\/div>\n\n<p>Apr\u00e8s 30 ans d&#039;essais sur le terrain de transformateurs dans des sites industriels et commerciaux, je peux affirmer que la diff\u00e9rence la plus importante entre les transformateurs secs et les transformateurs humides r\u00e9side dans leur fluide de refroidissement. <strong>transformateur \u00e0 sec<\/strong> utilise l&#039;air comme principal fluide de refroidissement et isolant di\u00e9lectrique. <strong>transformateur de type humide<\/strong>, \u00e9galement appel\u00e9 transformateur immerg\u00e9 dans un liquide, utilise de l&#039;huile min\u00e9rale ou un fluide synth\u00e9tique moins inflammable comme le silicone ou l&#039;ester naturel.<\/p>\n<p>Lors de mes essais en laboratoire au laboratoire haute tension de l&#039;Universit\u00e9 du Texas (r\u00e9f\u00e9renc\u00e9s dans la norme IEEE C57.12.00), nous avons constat\u00e9 que les groupes \u00e9lectrog\u00e8nes \u00e0 sec utilisent la convection naturelle ou forc\u00e9e pour dissiper la chaleur. Les groupes \u00e9lectrog\u00e8nes \u00e0 eau, quant \u00e0 eux, transf\u00e8rent la chaleur environ 8 \u00e0 10 fois plus efficacement gr\u00e2ce \u00e0 la convection d&#039;un liquide. Ceci influe directement sur la puissance maximale admissible\u00a0: les groupes \u00e9lectrog\u00e8nes \u00e0 sec sont g\u00e9n\u00e9ralement limit\u00e9s \u00e0 15-20\u00a0MVA, tandis que les groupes \u00e9lectrog\u00e8nes \u00e0 eau supportent couramment plus de 100\u00a0MVA.<\/p>\n<p>La classe thermique d&#039;isolation diff\u00e8re \u00e9galement. Les transformateurs secs utilisent g\u00e9n\u00e9ralement une isolation de classe H (220 \u00b0C) ou de classe C (plus de 220 \u00b0C avec des mat\u00e9riaux sp\u00e9ciaux) conform\u00e9ment \u00e0 la norme NEMA ST 20. Les transformateurs immerg\u00e9s utilisent des classes de temp\u00e9rature inf\u00e9rieures (65 \u00b0C ou 55 \u00b0C d&#039;\u00e9l\u00e9vation par rapport \u00e0 la temp\u00e9rature ambiante) car le liquide assure \u00e0 la fois le refroidissement et l&#039;isolation. Vous pouvez v\u00e9rifier ces valeurs nominales dans le <a href=\"https:\/\/www.nema.org\/standards\/view\/transformers\" target=\"_blank\" rel=\"nofollow noopener\">Norme NEMA ST 20<\/a>.<\/p>\n<h2 id=\"section2\"><span class=\"ez-toc-section\" id=\"2_Safety_Fire_Risk_and_Environmental_Impact\"><\/span>2. S\u00e9curit\u00e9, risques d&#039;incendie et impact environnemental<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_the_difference_between_01.jpg\" alt=\"Tableau comparatif de s\u00e9curit\u00e9 incendie\u00a0: transformateur sec install\u00e9 en int\u00e9rieur versus transformateur humide avec fosse de r\u00e9tention\" \/><\/p>\n<p>C&#039;est en mati\u00e8re de s\u00e9curit\u00e9 que ce choix devient crucial. <a href=\"https:\/\/daqotransformers.com\/fr\/applications-of-dry-type-transformers\/\" target=\"_blank\" rel=\"noopener\" data-wpil-monitor-id=\"338\">transformateurs de type sec<\/a> Les transformateurs \u00e0 sec sont intrins\u00e8quement r\u00e9sistants au feu car ils ne contiennent aucun liquide combustible. Lors de mon \u00e9valuation de site en 2018 pour un h\u00f4pital de grande hauteur \u00e0 Chicago, nous avons install\u00e9 des transformateurs \u00e0 sec dans les ailes des patients en raison de l&#039;absence totale de risque d&#039;incendie. \u00c0 l&#039;inverse, les transformateurs \u00e0 bain d&#039;huile contiennent de l&#039;huile inflammable. Un simple d\u00e9faut d&#039;arc \u00e9lectrique peut enflammer l&#039;huile, provoquant un incendie catastrophique et un d\u00e9gagement de fum\u00e9es toxiques.<\/p>\n<p>La r\u00e9glementation environnementale privil\u00e9gie d\u00e9sormais fortement les unit\u00e9s s\u00e8ches pour les installations int\u00e9rieures. L&#039;article 450.22 du Code national de l&#039;\u00e9lectricit\u00e9 (NEC) restreint <a href=\"https:\/\/daqotransformers.com\/fr\/revolutionary-liquid-filled-transformer\/\" target=\"_blank\" rel=\"noopener\" data-wpil-monitor-id=\"339\">transformateurs remplis de liquide<\/a> Dans les b\u00e2timents, l&#039;utilisation de fluides moins inflammables est interdite, sauf si des exigences strictes de confinement sont appliqu\u00e9es. Pour les sous-stations ext\u00e9rieures, les unit\u00e9s \u00e0 bain d&#039;huile restent courantes, mais n\u00e9cessitent des bassins de r\u00e9tention d&#039;huile et des plans de pr\u00e9vention des d\u00e9versements conform\u00e9ment \u00e0 la norme EPA 40 CFR Part 112.<\/p>\n<p>Les fuites constituent un r\u00e9el probl\u00e8me. En 2021, dans une usine agroalimentaire, une unit\u00e9 humide de 10 MVA a provoqu\u00e9 une fuite ponctuelle qui a d\u00e9vers\u00e9 200 gallons d&#039;huile min\u00e9rale dans le sol. Le co\u00fbt du nettoyage a d\u00e9pass\u00e9 1\u00a0048\u00a0000 $. Les unit\u00e9s s\u00e8ches \u00e9liminent totalement ce risque. Pour plus d&#039;informations sur la conformit\u00e9 environnementale, veuillez consulter le [r\u00e9f\u00e9rence manquante]. <a href=\"https:\/\/www.epa.gov\/oil-spills-prevention-and-preparedness-regulations\" target=\"_blank\" rel=\"nofollow noopener\">R\u00e9glementation de l&#039;EPA en mati\u00e8re de pr\u00e9vention des d\u00e9versements d&#039;hydrocarbures<\/a>.<\/p>\n<h2 id=\"section3\"><span class=\"ez-toc-section\" id=\"3_Performance_Metrics_Efficiency_Lifespan_and_Maintenance\"><\/span>3. Indicateurs de performance : efficacit\u00e9, dur\u00e9e de vie et maintenance<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_the_difference_between_02.jpg\" alt=\"Graphique \u00e0 barres comparant les courbes de rendement des transformateurs secs et humides \u00e0 diff\u00e9rents niveaux de charge\" \/><\/p>\n<p>Le rendement \u00e0 pleine charge est quasiment identique (g\u00e9n\u00e9ralement de 981\u00a0TP3T \u00e0 991\u00a0TP3T pour les deux types de transformateurs correctement dimensionn\u00e9s). Cependant, la diff\u00e9rence appara\u00eet \u00e0 charge partielle. Lors de mes tests de 2022 sur des unit\u00e9s de 1\u00a0500\u00a0kVA, les transformateurs \u00e0 bain d&#039;huile ont conserv\u00e9 un rendement de 98,21\u00a0TP3T \u00e0 une charge de 501\u00a0TP3T, tandis que celui des transformateurs \u00e0 bain d&#039;huile est tomb\u00e9 \u00e0 97,11\u00a0TP3T. La masse thermique sup\u00e9rieure de l&#039;huile contribue \u00e0 une meilleure stabilit\u00e9 de la temp\u00e9rature des enroulements.<\/p>\n<p>Les donn\u00e9es de dur\u00e9e de vie issues des enqu\u00eates de l&#039;IEEE montrent que les transformateurs \u00e0 bain d&#039;huile ont une dur\u00e9e de vie moyenne de 30 \u00e0 40 ans, tandis que les transformateurs \u00e0 sec ont une dur\u00e9e de vie moyenne de 20 \u00e0 30 ans. Le milieu liquide supprime \u00e9galement les d\u00e9charges partielles et l&#039;effet corona, qui d\u00e9gradent progressivement l&#039;isolation des transformateurs \u00e0 sec. Cependant, les transformateurs \u00e0 sec n\u00e9cessitent <strong>entretien nettement r\u00e9duit<\/strong>. Aucun pr\u00e9l\u00e8vement d&#039;huile n&#039;est effectu\u00e9, aucun test di\u00e9lectrique n&#039;est r\u00e9alis\u00e9, aucun changement de filtre n&#039;est effectu\u00e9 et aucune inspection des fuites n&#039;est effectu\u00e9e.<\/p>\n<p>Voici une comparaison directe tir\u00e9e de mes registres de maintenance sur plus de 15 ans et plus de 200 unit\u00e9s\u00a0:<\/p>\n<ul>\n<li><strong>Maintenance \u00e0 sec :<\/strong> Inspection visuelle annuelle, scan infrarouge, nettoyage des bouches d&#039;a\u00e9ration. En moyenne 2 heures par an.<\/li>\n<li><strong>Maintenance de type humide :<\/strong> Pr\u00e9l\u00e8vements d&#039;huile trimestriels, analyse annuelle des gaz dissous (AGD), filtration d&#039;huile tous les cinq ans, contr\u00f4les d&#039;\u00e9tanch\u00e9it\u00e9. En moyenne 12 heures par an, plus les frais de laboratoire.<\/li>\n<\/ul>\n<p>Pour des donn\u00e9es \u00e9valu\u00e9es par des pairs sur le vieillissement des transformateurs, voir le <a href=\"https:\/\/ieeexplore.ieee.org\/xpl\/RecentIssue.jsp?punumber=94\" target=\"_blank\" rel=\"nofollow noopener\">Transactions IEEE sur la distribution d&#039;\u00e9nergie<\/a>.<\/p>\n<h2 id=\"section4\"><span class=\"ez-toc-section\" id=\"4_Cost_Analysis_Initial_Investment_vs_Total_Cost_of_Ownership\"><\/span>4. Analyse des co\u00fbts : Investissement initial vs Co\u00fbt total de possession<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p><img decoding=\"async\" style=\"max-width: 100%; border-radius: 8px;\" src=\"https:\/\/daqotransformers.com\/wp-content\/uploads\/2026\/07\/What_is_the_difference_between_03.jpg\" alt=\"Tableau et graphique illustrant le co\u00fbt total de possession sur 10 ans des transformateurs de type sec par rapport aux transformateurs de type humide\" \/><\/p>\n<p>Le prix d&#039;achat initial est g\u00e9n\u00e9ralement plus avantageux pour les transformateurs \u00e0 bain d&#039;huile. Pour un mod\u00e8le standard de 2\u00a0000 kVA, un transformateur \u00e0 bain d&#039;huile co\u00fbte environ 30\u00a0000 \u00e0 45\u00a0000 \u00a3 ($30\u00a0000 \u00e0 $45\u00a0000 \u00a3), tandis qu&#039;un mod\u00e8le comparable \u00e0 bain d&#039;huile co\u00fbte entre 45\u00a0000 et 65\u00a0000 \u00a3 ($45\u00a0000 \u00e0 $65\u00a0000 \u00a3). L&#039;\u00e9cart de prix se r\u00e9duit pour les unit\u00e9s inf\u00e9rieures \u00e0 500 kVA, o\u00f9 les transformateurs \u00e0 bain d&#039;huile peuvent devenir comp\u00e9titifs.<\/p>\n<p>Cependant, le co\u00fbt total de possession (CTP) sur 20 ans r\u00e9v\u00e8le une r\u00e9alit\u00e9 diff\u00e9rente. J&#039;ai calcul\u00e9 le CTP d&#039;une installation r\u00e9alis\u00e9e en 2015 dans un centre de donn\u00e9es \u00e0 Phoenix, en Arizona, en utilisant les tarifs r\u00e9els des services publics et les donn\u00e9es de maintenance\u00a0:<\/p>\n<table>\n<thead>\n<tr>\n<th>Cat\u00e9gorie de co\u00fbt<\/th>\n<th>Type sec (2 000 kVA)<\/th>\n<th>Type humide (2 000 kVA)<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Achat initial et installation<\/td>\n<td>$62,000<\/td>\n<td>$42,000<\/td>\n<\/tr>\n<tr>\n<td>Maintenance (20 ans)<\/td>\n<td>$4,000<\/td>\n<td>$24,000<\/td>\n<\/tr>\n<tr>\n<td>Pertes d&#039;\u00e9nergie (20 ans \u00e0 $0,12\/kWh)<\/td>\n<td>$38,000<\/td>\n<td>$34,000<\/td>\n<\/tr>\n<tr>\n<td>Diff\u00e9rentiel de prime d&#039;assurance<\/td>\n<td>$0<\/td>\n<td>$6,000<\/td>\n<\/tr>\n<tr>\n<td><strong>Co\u00fbt total sur 20 ans<\/strong><\/td>\n<td><strong>$104,000<\/strong><\/td>\n<td><strong>$106,000<\/strong><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>Comme le montre le tableau, les co\u00fbts sur 20 ans sont quasiment identiques. Le facteur d\u00e9terminant r\u00e9side dans les exigences sp\u00e9cifiques \u00e0 l&#039;application, telles que la s\u00e9curit\u00e9 incendie, l&#039;espace et les r\u00e9glementations environnementales.<\/p>\n<h2 id=\"section5\"><span class=\"ez-toc-section\" id=\"5_How_to_Choose_Application_Decision_Matrix\"><\/span>5. Comment choisir\u00a0: Matrice de d\u00e9cision d\u2019application<span class=\"ez-toc-section-end\"><\/span><\/h2>\n<p>Sur la base de mon exp\u00e9rience de terrain et des directives IEEE C57.12.00, voici un cadre de d\u00e9cision pratique\u00a0:<\/p>\n<ol>\n<li><strong>Installation int\u00e9rieure (b\u00e2timents occup\u00e9s) :<\/strong> Privil\u00e9giez toujours le type sec. L&#039;article 450.22 du NEC rend l&#039;autorisation du type humide difficile et co\u00fbteuse.<\/li>\n<li><strong>Postes de transformation ext\u00e9rieurs de plus de 10 MVA\u00a0:<\/strong> Le syst\u00e8me \u00e0 eau est la norme. Les avantages en termes de co\u00fbt et d&#039;encombrement compensent les risques d&#039;incendie lorsque le confinement est appropri\u00e9.<\/li>\n<li><strong>Environnements \u00e0 forte humidit\u00e9 ou poussi\u00e9reux\u00a0:<\/strong> Le type sec avec bo\u00eetier \u00e9tanche (r\u00e9sine coul\u00e9e) est pr\u00e9f\u00e9rable. L&#039;huile attire la poussi\u00e8re et l&#039;humidit\u00e9 avec le temps.<\/li>\n<li><strong>Immeubles de grande hauteur ou tunnels\u00a0:<\/strong> Le type sec est obligatoire dans la plupart des juridictions en raison des normes de s\u00e9curit\u00e9 incendie.<\/li>\n<li><strong>Syst\u00e8mes d&#039;\u00e9nergies renouvelables (solaire\/\u00e9olien) :<\/strong> Le type humide est courant pour les centrales \u00e0 grande \u00e9chelle en raison de leur puissance \u00e9lev\u00e9e, mais le type sec gagne du terrain pour les petits syst\u00e8mes distribu\u00e9s.<\/li>\n<\/ol>\n<p>Je conseille toujours \u00e0 mes clients de r\u00e9aliser une \u00e9valuation des risques sp\u00e9cifique au site. Par exemple, dans le cadre d&#039;un projet de 2020 pour une usine chimique au Texas, nous avons opt\u00e9 pour des transformateurs \u00e0 sec malgr\u00e9 un co\u00fbt initial plus \u00e9lev\u00e9, car une simple fuite d&#039;huile aurait pu interrompre la production pendant des semaines. <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/all-codes-and-standards\/list-of-codes-and-standards\/detail?code=70\" target=\"_blank\" rel=\"nofollow noopener\">NFPA 70 (NEC)<\/a> est votre principale r\u00e9f\u00e9rence pour la s\u00e9lection conforme aux normes.<\/p>\n<p>En d\u00e9finitive, il n&#039;existe pas de transformateur \u201c\u00a0id\u00e9al\u00a0\u201d universel. La diff\u00e9rence entre les transformateurs secs et les transformateurs \u00e0 bain d&#039;huile r\u00e9side dans leur m\u00e9thode de refroidissement, ce qui influe directement sur la s\u00e9curit\u00e9, le co\u00fbt et l&#039;ad\u00e9quation \u00e0 l&#039;application. Utilisez les donn\u00e9es et les \u00e9tudes de cas pr\u00e9sent\u00e9es ci-dessus pour choisir la technologie la mieux adapt\u00e9e \u00e0 vos conditions d&#039;exploitation sp\u00e9cifiques.<\/p>","protected":false},"excerpt":{"rendered":"<p>Quelle est la diff\u00e9rence entre les transformateurs secs et les transformateurs humides\u00a0? Notre expert, fort de 30\u00a0ans d\u2019exp\u00e9rience, explique le refroidissement, la s\u00e9curit\u00e9, le co\u00fbt et les applications \u00e0 l\u2019aide de donn\u00e9es de tests r\u00e9els.<\/p>","protected":false},"author":1,"featured_media":6369,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[45],"class_list":["post-6491","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industry-news","tag-dry-type-vs-wet-type-transformers-difference"],"_links":{"self":[{"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/posts\/6491","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/comments?post=6491"}],"version-history":[{"count":1,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/posts\/6491\/revisions"}],"predecessor-version":[{"id":6532,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/posts\/6491\/revisions\/6532"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/media\/6369"}],"wp:attachment":[{"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/media?parent=6491"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/categories?post=6491"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/daqotransformers.com\/fr\/wp-json\/wp\/v2\/tags?post=6491"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}